Basic Info.
Model NO.
TYKCT-FA120*80
Insulating Medium
Common Insulating Materials
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Coil Number
Customized
Coil Structure
Autotransformer
Transport Package
Export Carton
Trademark
Blue Jay
Origin
Chongqing, China
Production Capacity
1000 Piece/Pieces Per Month
Product Description
TYKCT-FA120*80 is used for the measurement of alternating current when the current to be measured is too large to apply directly to the measuring instrument. The standard output currents are /1A and /5A. The precision is indicated by the class, the most used being class 0.5 (0.5% error) and class 1 (1% error).
In the bus bar current transformers, the current cable to be measured must pass through the central hole, without the need to cut it. They are the most used because of their good Precision/Price ratio for intensities greater than 50A.
In the bus bar current transformers, the current cable to be measured must pass through the central hole, without the need to cut it. They are the most used because of their good Precision/Price ratio for intensities greater than 50A.
* Beautiful appearance and small size
* Terminal output, flexible wiring;
* Beautiful appearance and small size;
* Split core design, small core loss, and high precision;
* There is no need to disconnect the bus, and the installation is convenient;
* Snap type opening and closing structure, convenient opening and closing.
* Beautiful appearance and small size;
* Split core design, small core loss, and high precision;
* There is no need to disconnect the bus, and the installation is convenient;
* Snap type opening and closing structure, convenient opening and closing.
Rated secondary current 5A/1A) | | | | | ||||
Model | Rated primary current (A) | Load (VA) | | | ||||
| | Class 0.5S | Class 0.5 | Class 1 | ||||
TYKCT-YJ25 | 50 | / | / | 1 | ||||
| 100 | / | 1 | 2.5 | ||||
| 150 | 1 | 1.5 | 2.5 | ||||
| 200 | 1.5 | 2.5 | 5 | ||||
| 250 | 2.5 | 3.75 | 5 | ||||
| 300 | 3.75 | 5 | 7.5 | ||||
(Rated secondary output mA/mV) | | | | | ||||
Rated primary current | 0~300A | | | | ||||
continuous current | 360A | | | | ||||
Rated secondary current | 0~100mA | | | | ||||
Rated secondary voltage | 0~1V | | | | ||||
Load Resistance | 0~10Ω | | | | ||||
Accuracy class | 0.5s/0.5 | | | | ||||
Other Equipment maximum voltage: 0.66kV Rated input: 0~2000A Rated output: 5A/1A/mA/mV Working frequency: 50Hz~60Hz Working temperature: -40~+85 Relative humidity: ≤90%, when the temperature is 40°C Power frequency withstand voltage: 3000V/1mA/1min(50Hz) Insulation resistance: DC500V/1000MΩ/min | | | | | ||||
| | | | |
Note: If you have any puzzles or requests about this product (including model number, data sheet or any other aspects), please contact us immediately.
* Sub-Metering Accurate Measurement
* Data Loggers to analyze Building & Machinery Performance
* Digital Fault Recorders
* Smart Grid Application Features, Load Center
* Three Phase Balance Control
* In-Factory Display, or In-Home Display
* Inverters for Solar & Wind Turbine Systems
* Power Measurement Device for PLC
* Data Loggers to analyze Building & Machinery Performance
* Digital Fault Recorders
* Smart Grid Application Features, Load Center
* Three Phase Balance Control
* In-Factory Display, or In-Home Display
* Inverters for Solar & Wind Turbine Systems
* Power Measurement Device for PLC