Basic Info.
Model NO.
BC-T00356A
Usage
Rectifier Transformer, Combined Transformer, Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Silicon Steel Sheet
Brand
Bc Power
Rated Output Voltage
400V/550V +/-3%
Rated Output Current
1470A
Isolation Grade
Class H
Working Frequency
45Hz/65Hz
Rated Power
1400kVA
Noise
<65dB
Temperature Rise
<110K
Weight
Nearly 3400kg
Dimension
1290mm*990mm*1650mm
Transport Package
Wooden Case
Specification
1400KVA, 400V/400V/550V
Trademark
BC POWER or Customized
Origin
Dongguan City, Guangdong Province, China
Production Capacity
2000-3000 PCS/Year
Product Description
Electric Characteristics
Dongguan Baocheng Power Technology Co., Ltd. is a full program of R & D, manufacturing and sales as one of the magnetic devices. It specializes in designing and customizing the "magnetic devices" of modern power electronic systems for customers, including applications from power frequency to high frequency, from low voltage to high voltage, and high frequency and high voltage. The system covers all kinds of dry / water-cooled inductors, reactors, transformers and transformer cabinets. The power range of the product covers 50VA-5000KVA, the frequency range covers 50Hz-50 KHz, the voltage level covers all kinds of high / low voltage, high / frequency products, and the K- coefficient of application in the non linear load environment. Press (patent product) etc.
Company founded in 2010. The company's headquarters is located in Jinhe community of Zhangmutou town in Dongguan. The practical area of the factory is about 10 thousand square meters. It sets up distribution outlets in East China, North China, northwest and other places. It is a high-tech enterprise in Dongguan. The company has more than 20 patents.
No. | Parameter | Test Terminal | Test value | Test condition | Standard test instrument |
1 | No-load output voltage | a1-b1, b1-c1, a1-c1 a-b, b-c, a-c | 400V(+/-3%) 550V(+/-3%) | Input: A-B, B-C,C-A 400V | Transformer comprehensive tester |
2 | Rated load voltage | a1-b1, b1-c1, a1-c1 a-b, b-c, a-c | 400V(+/-5%) 550V(+/-5%) | ||
3 | Rated load power | a1-b1, b1-c1, a1-c1 a-b, b-c, a-c | 1019KVA 1400KVA | ||
4 | Rated load current | a1-b1, b1-c1, a1-c1 a-b, b-c, a-c | 1470A 1470A | ||
5 | Coil connection group | Dyn11 | |||
6 | Short circuit impedance | average voltage between A/B/C is 400V | (6-8)% | Short circuit a/b/c, input current of B phase reaches 2021A | |
7 | Insulation resistance | Coil to core Primary to secondary | >100MΩ | 1000V DC | |
8 | Dielectric strength | Primary to GND, core, secondary | No arcing or breakdown | 3000VAC/60s | Power frequency voltage tester |
9 | Temperature rise | <110K, rated full load, air forced cooling | |||
10 | Noise | <65dB, rated full load at 1 meter distance | |||
11 | Insulation grade | Class H | |||
12 | Cooling type | Air forced cooling(3 each left and right top blowing axial flow fans in the lower part of the transformer, the fans are supplied with single-phase 220V power supply) | |||
13 | Efficiency | >99% (25ºC) | |||
14 | Overvoltage | -10%~+15% | |||
15 | Overload | No overload | |||
16 | Frequency | 45~65Hz | |||
17 | Special requirement | The output of 400V and 550V windings do not work simultaneously | |||
18 | Operating temperature | -25~50ºC | |||
19 | Storage temperature | -40~70 ºC | |||
20 | Altitude | 2000m (derate 1% for every 100m increase over 2000m) | |||
21 | Operating humidity | Relative: 0%~95% Absolute: <29g/m3, without condensation | |||
22 | Weight | About 3400 kg |